HealthInno × NMSU Arrowhead Center
Interactive technology walkthrough
Binary Surface (BIS) · Persistent Antimicrobial Protection

A surface that keeps its disinfectant.

Every disinfectant applied to a hospital surface today is transient — it spreads, evaporates, or is wiped away, and the protection goes with it. NMSU's Binary Surface is engineered at the micro- and nano-scale to soak up and hold a functional liquid by capillary force, so the surface stays protected between cleanings. Below, put a conventional surface and a BIS surface through the same abuse and watch which one keeps working.

Dr. Sarada Kuravi · Dr. Krishna Kota · NMSU Arrowhead Patent application filed Stage: lab prototype → pilot readiness Preliminary: no detectable virus at 1 h & 2 h (BIS-DES)
1 in 31
hospital patients has a healthcare-associated infection on any given dayi
$10–15B
antimicrobial coatings market, 2025 · growing ~11–13%/yri
~40%+
of that market is healthcare — the largest segmenti
Replenish
not replace — re-infuse the liquid; the engineered surface staysi
TWO SURFACES · ONE CHALLENGE · LIVE

Conventional flat surface today

Liquid retained100%
Recoverable virus vs. untreated
—

BIS engineered surface NMSU

Liquid retained100%
Recoverable virus vs. untreated
—
🧪Both surfaces freshly treated. Apply a challenge above — touch it, wipe it, rinse it, shake it, let time pass — and compare.Illustrative model of the preliminary lab observations, not measured data.

How it works

The engineering is in the surface itself. Instead of coating a flat surface with something that will wear off, BIS turns the surface into a reservoir — think of a metal that behaves like a paper towel — and lets you choose what it holds.

Where it fits: high-touch, hard, non-critical surfaces

Surfaces that are touched constantly and cleaned on a schedule — where the gap between cleanings is exactly the problem.

🚪
Door handles
hundreds of touches/day
🛏️
Bed rails
patient & staff contact
🩺
IV poles
moved room to room
🖥️
Nurse-station counters
shared workspace
🛗
Elevator buttons
public high-touch
🚰
Sink & fixture handles
wet, frequent use

What's proven, and what the pilot-readiness phase answers

We're deliberately honest here: the science is real and promising, and the next questions are exactly the ones an operator would ask.

Demonstrated in the lab preliminary

  • Infused liquid stays in the surface through shaking, movement, flowing liquid, and paper-towel wiping.
  • Works with three formulations: a commercial disinfectant, eucalyptus oil, and eucalyptus oil with copper nanoparticles.
  • Disinfectant-infused BIS (BIS-DES) showed no detectable infectious virus (PFU) at 1 h and 2 h on tested substrates.
  • Copper-nanoparticle BIS (BIS-NP) showed substantial reductions in recoverable virus vs. controls.
  • Built on NMSU's patented surface-modification method — grooves, micro- and nano-cavities that make metal ultra-wettable.

The pilot-readiness plan

Faculty Innovation to Pilot pathway · up to $25,000 · estimated 5 months. Ends with a recommended healthcare use case, data, and a pilot-ready plan.

Month 1
Setup & baseline
Protocols, fabricate samples, baseline retention, open stakeholder conversations.
Months 1–2
Retention & durability
Controlled retention studies; find what disrupts the liquid; test replenishment.
Months 2–3
Antimicrobial & application
Targeted viral/antimicrobial validation; compare applications; pick the use case.
Months 3–5
Pilot-readiness planning
Refine configuration; engage the partner; define objectives, criteria, approvals.
Retention & persistence dataDurability & failure conditionsMaintenance / replenishment criteria Performance & application matrixRecommended first use casePilot-readiness plan & success criteria

Ways to engage

A pilot site hasn't been chosen yet — the ideal partner is a healthcare organization with frequently touched, hard, non-critical surfaces on a routine cleaning schedule.

Host the pilot siteShape the first use caseCo-develop a formulationLicense the IPInvest / sponsor

Interactive interpretation for demonstration only. The simulation above is an illustrative model of preliminary laboratory observations reported by the NMSU team and does not represent measured retention, durability, or antimicrobial data. Results were obtained under specific laboratory conditions on tested substrates. BIS is intended to complement, not replace, established cleaning and disinfection practices. No regulatory claims are made; requirements depend on the final configuration, agent, and intended use.